Masana Energy Solutions HSS Customer Guide
Organisational measures to prevent/limit release from site: Do not apply industrial sludge to natural soils. Sludge should be incinerated, contained or reclaimed Conditions and measures related to sewage treatment plant: Not applicable as there is no release to wastewater. Conditions and measures related to external treatment of waste for disposal: Combustion emissions limited by required exhaust emission controls. Combustion emissions considered in regional exposure assessment. External treatment and disposal of waste should comply with applicable local and/or national regulations. Conditions and measures related to external recovery of waste: This substance is consumed during use and no waste from the substance is generated. Treat on-site wastewater (prior to receiving water discharge) to provide the required removal efficiency of EC number ... % | EC number ... % 265-045-2 … 94.0 | 265-082-4 … 86.3 265-058-3 … 89.5 | 269-777-3 … 93.4 265-064-6 … 90.0 | 270-675-6 … 61.1 265-076-1 … 98.3 | 273-263-4 … 23.1 265-081-9 … 71.6 | 295-511-0 … 84.1 If discharging to municipal sewage treatment plant, provide the required on-site wastewater removal efficiency of typical value: 0.0% EC number 265-076-1 … 77.4%. Estimated substance removal from wastewater via on-site sewage treatment EC number ... % | EC number ... % 265-045-2 … 95.1 | 265-082-4 … 87.6 265-058-3 … 90.4 | 269-777-3 … 94.0 265-064-6 … 92.5 | 270-675-6 … 94.2 265-076-1 … 92.7 | 273-263-4 … 94.0 265-081-9 … 93.9 | 295-511-0 … 93.2 Total efficiency of removal from wastewater after on-site and off-site (municipal treatment plant) RMMs EC number ... % | EC number ... % 265-045-2 … 95.1 | 265-082-4 … 87.6 265-058-3 … 90.4 | 269-777-3 … 94.0 265-064-6 … 92.5 | 270-675-6 … 94.2 265-076-1 … 98.3 | 273-263-4 … 94.0 265-081-9 … 93.9 | 295-511-0 … 93.2 Maximum allowable site tonnage (M Safe ) based on release following total wastewater treatment removal EC number ... kg/day | EC number ... kg/day 265-045-2 … 9.7E+05 | 265-082-4 … 3.1E+04 265-058-3 … 4.8E+05 | 269-777-3 … 1.8E+06 265-064-6 … 1.4E+05 | 270-675-6 … 7.2E+06 265-076-1 … 3.1E+05 | 273-263-4 … 2.6E+05 265-081-9 … 7.3E+06 | 295-511-0 … 2.3E+05 Assumed on-site sewage treatment plant flow 2.0E+03 (m3/d) EC number ... Value | EC number ... Value 265-045-2 … 5.2E-01 | 265-082-4 … 3.0E-01 265-058-3 … 8.2E-01 | 269-777-3 … 6.6E-01 265-064-6 … 1.0E-01 | 270-675-6 … 6.9E-01 265-076-1 … 3.4E-01 | 273-263-4 … 1.9E-01 265-081-9 … 6.4E-01 | 295-511-0 … 4.0E-01 EC number ... Value | EC number ... Value 265-045-2 … 8.2E-01 | 265-082-4 … 9.1E-01 265-058-3 … 9.1E-01 | 269-777-3 … 9.1E-01 265-064-6 … 7.5E-01 | 270-675-6 … 1.5E-01 265-076-1 … 9.1E-01 | 273-263-4 … 7.7E-02 265-081-9 … 2.2E-01 | 295-511-0 … 4.3E-01 RCR - Air Compartment Driven: RCR - Water Compartment Driven: Section 3: Exposure estimation and reference to its source Exposure assessment (environment): Hydrocarbon Block Method (Petrorisk) Exposure assessment (human): The ECETOC TRA tool has been used to estimate workplace exposures unless otherwise indicated. Exposure estimation and reference to its source - Workers Exposure estimation and reference to its source - Environment Section 4: Guidance to check compliance with the exposure scenario 25/38 Use in fuel (Heavy fuel oil) - Industrial Fuel Oil, residual
Made with FlippingBook
RkJQdWJsaXNoZXIy MTI4MTE=