Masana Energy Solutions HSS Customer Guide
Operation of solids filtering equipment: Provide a good standard of general ventilation (not less than 3 to 5 air changes per hour). Avoid carrying out activities involving exposure for more than 4 hours per day. Wear chemical- resistant gloves (tested to EN374) in combination with 'basic' employee training. Bulk product storage: Store substance within a closed system. Provide a good standard of general ventilation (not less than 3 to 5 air changes per hour). Avoid carrying out operation for more than 4 hours. Wear chemical-resistant gloves (tested to EN374) in combination with 'basic' employee training. Use in fuel (Closed systems): Wear chemical-resistant gloves (tested to EN374) in combination with 'basic' employee training. Equipment cleaning and maintenance: Drain down system prior to equipment break-in or maintenance. Wear chemical-resistant gloves (tested to EN374) in combination with specific activity training. Retain drain-downs in sealed storage pending disposal or for subsequent recycle. Section 2.2: Control of environmental exposure Product characteristics: Substance is complex UVCB. Predominantly hydrophobic Frequency and duration of use: Continuous release Environment factors not influenced by risk management: Technical conditions and measures at process level (source) to prevent release: Common practices vary across sites thus conservative process release estimates used. Technical on-site conditions and measures to reduce or limit discharges, air emissions and releases to soil: EC number 265-045-2 265-082-4 265-058-3 269-777-3 265-064-6 295-511-0 Risk from environmental exposure is driven by freshwater sediment. If discharging to municipal sewage treatment plant, no on-site wastewater treatment required. EC number 265-076-1: Risk from environmental exposure is driven by freshwater sediment. If discharging to domestic sewage treatment plant, additional onsite wastewater treatment required. EC number 265-081-9: Risk from environmental exposure is driven by humans via indirect exposure (primarily inhalation). If discharging to municipal sewage treatment plant, no on-site wastewater treatment required. EC number 273-263-4: Risk from environmental exposure is driven by humans via indirect exposure (primarily ingestion). If discharging to municipal sewage treatment plant, no on-site wastewater treatment required. EC number 270-675-6: Risk from environmental exposure is driven by terrestrial secondary poisoning. If discharging to municipal sewage treatment plant, no on- site wastewater treatment required. Emission days 300 days per year Local freshwater dilution factor 10 Local marine water dilution factor 100 Release fraction to air from process (initial release prior to RMM) EC number ... Value | EC number ... Value 265-045-2 … 1.0E-02 | 265-082-4 … 5.0E-03 265-058-3 … 2.0E-03 | 269-777-3 … 2.0E-03 265-064-6 … 5.0E-03 | 270-675-6 … 2.0E-04 265-076-1 … 5.0E-03 | 273-263-4 … 5.0E-03 265-081-9 … 2.0E-03 | 295-511-0 … 5.0E-03 Release fraction to soil from process (initial release prior to RMM) 0.0 EC number ... Value | EC number ... Value 265-045-2 … 7.4E-06 | 265-082-4 … 7.7E-06 265-058-3 … 2.2E-06 | 269-777-3 … 3.9E-06 265-064-6 … 1.0E-05 | 270-675-6 … 1.9E-07 265-076-1 … 1.0E-05 | 273-263-4 … 1.0E-05 265-081-9 … 1.9E-07 | 295-511-0 … 1.0E-05 Release fraction to wastewater from process (initial release prior to RMM) Treat air emission to provide a typical removal efficiency of 95% 24/38 Use in fuel (Heavy fuel oil) - Industrial Fuel Oil, residual
Made with FlippingBook
RkJQdWJsaXNoZXIy MTI4MTE=