Masana Energy Solutions HSS Customer Guide
EC number 265-058-3; 270-675-6: Risk from environmental exposure is driven by terrestrial secondary poisoning. If discharging to municipal sewage treatment plant, no on- site wastewater treatment required. Organisational measures to prevent/limit release from site: Do not apply industrial sludge to natural soils. Sludge should be incinerated, contained or reclaimed Conditions and measures related to sewage treatment plant: Not applicable as there is no release to wastewater. Conditions and measures related to external treatment of waste for disposal: External treatment and disposal of waste should comply with applicable local and/or national regulations. Conditions and measures related to external recovery of waste: External recovery and recycling of waste should comply with applicable local and/or national regulations. Treat air emission to provide a typical removal efficiency of 0.0 % Treat on-site wastewater (prior to receiving water discharge) to provide the required removal efficiency of EC number ... % | EC number ... % 265-045-2 … 94.6 | 265-082-4 … 86.3 265-058-3 … 80.0 | 269-777-3 … 93.4 265-064-6 … 91.7 | 270-675-6 … 60.9 265-076-1 … 89.7 | 273-263-4 … 97.9 265-081-9 … 71.5 | 295-511-0 … 99.2 If discharging to municipal sewage treatment plant, provide the required on-site wastewater removal efficiency of typical value: 0.0% EC number ... Value 273-263-4 … 64.3 295-511-0 … 88.2 Estimated substance removal from wastewater via on-site sewage treatment EC number ... % | EC number ... % 265-045-2 … 95.1 | 265-082-4 … 87.6 265-058-3 … 90.4 | 269-777-3 … 94.0 265-064-6 … 92.5 | 270-675-6 … 94.2 265-076-1 … 92.7 | 273-263-4 … 94.0 265-081-9 … 93.9 | 295-511-0 … 93.2 Total efficiency of removal from wastewater after on-site and off-site (municipal treatment plant) RMMs EC number ... % | EC number ... % 265-045-2 … 95.1 | 265-082-4 … 87.6 265-058-3 … 90.4 | 269-777-3 … 94.0 265-064-6 … 92.5 | 270-675-6 … 94.2 265-076-1 … 92.7 | 273-263-4 … 97.9 265-081-9 … 93.9 | 295-511-0 … 99.2 Maximum allowable site tonnage (M Safe ) based on release following total wastewater treatment removal EC number ... kg/day | EC number ... kg/day 265-045-2 … 1.1E+05 | 265-082-4 … 5.9E+04 265-058-3 … 1.2E+05 | 269-777-3 … 1.1E+05 265-064-6 … 1.1E+05 | 270-675-6 … 1.1E+05 265-076-1 … 1.4E+05 | 273-263-4 … 1.0E+05 265-081-9 … 2.8E+05 | 295-511-0 … 1.0E+05 Assumed on-site sewage treatment plant flow 2.0E+03 (m3/d) EC number ... Value | EC number ... Value 265-045-2 … 3.5E-01 | 265-082-4 … 9.3E-01 265-058-3 … 8.4E-01 | 269-777-3 … 6.5E-01 265-064-6 … 1.6E-01 | 270-675-6 … 7.0E-01 265-076-1 … 3.9E-01 | 273-263-4 … 2.3E-01 265-081-9 … 3.2E-01 | 295-511-0 … 4.8E-01 EC number ... Value | EC number ... Value 265-045-2 … 9.1E-01 | 265-082-4 … 9.1E-01 265-058-3 … 4.8E-01 | 269-777-3 … 9.1E-01 265-064-6 … 9.1E-01 | 270-675-6 … 1.5E-01 265-076-1 … 7.1E-01 | 273-263-4 … 9.1E-01 265-081-9 … 2.1E-01 | 295-511-0 … 9.1E-01 RCR - Air Compartment Driven: RCR - Water Compartment Driven: Section 3: Exposure estimation and reference to its source Exposure assessment (environment): Hydrocarbon Block Method (Petrorisk) Exposure estimation and reference to its source - Environment 21/38 Formulation and (re)packing of substances and mixtures (Heavy fuel oil) Fuel Oil, residual
Made with FlippingBook
RkJQdWJsaXNoZXIy MTI4MTE=