Masana Energy Solutions HSS Customer Guide
Organisational measures to prevent/limit release from site: Do not apply industrial sludge to natural soils. Sewage sludge should be incinerated, contained or reclaimed. Conditions and measures related to sewage treatment plant: Not applicable as there is no release to wastewater. Conditions and measures related to external treatment of waste for disposal: This substance is consumed during use and no waste from the substance is generated. Conditions and measures related to external recovery of waste: This substance is consumed during use and no waste from the substance is generated. If discharging to municipal sewage treatment plant, provide the required on-site wastewater removal efficiency of EC number ... % | EC number ... % 265-045-2 … 0.0 | 265-082-4 … 0.0 265-058-3 … 0.0 | 269-777-3 … 0.0 265-064-6 … 0.0 | 270-675-6 … 0.0 265-076-1 … 0.0 | 273-263-4 … 52.4 265-081-9 … 0.0 | 295-511-0 … 84.3 Estimated substance removal from wastewater via on-site sewage treatment EC number ... % | EC number ... % 265-045-2 … 95.1 | 265-082-4 … 87.6 265-058-3 … 90.4 | 269-777-3 … 94.0 265-064-6 … 92.5 | 270-675-6 … 94.2 265-076-1 … 92.7 | 273-263-4 … 94.0 265-081-9 … 93.9 | 295-511-0 … 93.2 Total efficiency of removal from wastewater after on-site and off-site (municipal treatment plant) RMMs EC number ... % | EC number ... % 265-045-2 … 95.1 | 265-082-4 … 87.6 265-058-3 … 90.4 | 269-777-3 … 94.0 265-064-6 … 92.5 | 270-675-6 … 94.2 265-076-1 … 92.7 | 273-263-4 … 97.1 265-081-9 … 93.9 | 295-511-0 … 98.9 Maximum allowable site tonnage (M Safe ) based on release following total wastewater treatment removal EC number ... kg/day | EC number ... kg/day 265-045-2 … 5.5E+04 | 265-082-4 … 5.5E+04 265-058-3 … 1.0E+05 | 269-777-3 … 5.5E+04 265-064-6 … 5.5E+04 | 270-675-6 … 7.3E+04 265-076-1 … 7.0E+04 | 273-263-4 … 5.0E+04 265-081-9 … 2.3E+05 | 295-511-0 … 5.0E+04 Assumed on-site sewage treatment plant flow 2.0E+03 (m3/d) EC number ... Value | EC number ... Value 265-045-2 … 3.5E-01 | 265-082-4 … 3.4E-04 265-058-3 … 1.5E-01 | 269-777-3 … 4.3E-03 265-064-6 … 1.1E-02 | 270-675-6 … 6.9E-01 265-076-1 … 1.7E-02 | 273-263-4 … 4.3E-03 265-081-9 … 6.7E-02 | 295-511-0 … 9.7E-03 EC number ... Value | EC number ... Value 265-045-2 … 9.1E-01 | 265-082-4 … 9.1E-01 265-058-3 … 4.8E-01 | 269-777-3 … 9.1E-01 265-064-6 … 9.1E-01 | 270-675-6 … 1.1E-02 265-076-1 … 7.1E-01 | 273-263-4 … 9.1E-01 265-081-9 … 2.2E-01 | 295-511-0 … 9.1E-01 RCR - Air Compartment Driven: RCR - Water Compartment Driven: Section 3: Exposure estimation and reference to its source Exposure assessment (environment): Hydrocarbon Block Method (Petrorisk) Exposure assessment (human): The ECETOC TRA tool has been used to estimate workplace exposures unless otherwise indicated. Exposure estimation and reference to its source - Workers Exposure estimation and reference to its source - Environment Section 4: Guidance to check compliance with the exposure scenario Environment Guidance is based on assumed operating conditions which may not be applicable to all sites; thus, scaling may be necessary to define appropriate site-specific risk management measures. Required removal efficiency for wastewater can be achieved using onsite/ offsite technologies, either alone or in combination. Required removal efficiency for air can be achieved using on-site technologies, either alone or in combination. Further details on scaling and control technologies are provided in SPERC factsheet. 32/38 Use as an intermediate (Heavy fuel oil) Fuel Oil, residual
Made with FlippingBook
RkJQdWJsaXNoZXIy MTI4MTE=